Quality items from Bonanza’s top-rated sellers.

Wigmors's booth earned a 99.9% satisfaction rating for providing an excellent experience from start to finish. View booth >>

Rendered at 11:27:45 05/09/25
Full-size item image
Primary image for Dual Temperature Accessory Head Fieldpiece ATH4 simultaneously measure calculate
Item image 1
Item image 2

Dual Temperature Accessory Head Fieldpiece ATH4 simultaneously measure calculate

£522.93 GBP
£539.11 More info
Ships from Poland Pl

Don't miss out on this item!

There is only 1 left in stock.

Shipping options

£14.81 to United Kingdom
Ships from Poland Pl

Offer policy

OBO - Seller accepts offers on this item. Details

Purchase protection

Payment options

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Shipping options

£14.81 to United Kingdom
Ships from Poland Pl

Offer policy

OBO - Seller accepts offers on this item. Details

Purchase protection

Payment options

PayPal accepted
PayPal Credit accepted
Venmo accepted
PayPal, MasterCard, Visa, Discover, and American Express accepted
Maestro accepted
Amazon Pay accepted
Nuvei accepted

Item traits

Category:

Other Air Conditioning & Heating

Quantity Available:

Only one in stock, order soon

Condition:

New

MPN:

ATH4

Producent:

Fieldpiece

Listing details

Seller policies:

View seller policies

Shipping discount:

No combined shipping offered

Posted for sale:

More than a week ago

Item number:

1514421007

Item description

Don't know cost of shipment to your country? - Please, tell us your postal code, instead of make order. Just clicked Buy and still don't know delivery cost? - Please, do not click second time. We'll estimate this cost. Termometr z podwojnym pomiarem wymiennymi termoparami Fieldpiece ATH4 Zastosowanie: rownoleg?y pomiar dwoch temperatur oraz Delty T, ustalanie temperatury przegrzania oraz dalsze zadania w zale?no?ci od pod??czonego urz?dzenia (np. z analizatorem HG3 okre?lanie temperatury wyj?ciowej z parownika, a z termopar? ATC3 sprawdzian zablokowanych filtrow). Parallel measurement of two temperatures and Delta T, temperature setting overheating and further tasks depending on the connected device (eg. the analyzer HG3 determining the starting temperature of the evaporator, and thermocouple test ATC3 blocked filters). Opis produktu: ATH4, jedna z g?owic pomiarowych jakie mo?na zastosowa? w miernikach Fieldpiece b?d? innych, umo?liwia rownoleg?e zmierzenie dwoch temperatur. Od zastosowanego rodzaju termopary zale?y co b?dzie przedmiotem pomiaru. W zestawie u?ytkownik otrzymuje dwie uniwersalne termopary typu K, ATB1. Jednak do g?owicy mo?na pod??czy? rownie? inne wersje: ATA1 - termopara ATB1 z zaciskiem (z tzw. krokodylkiem), ATAF1 - termopara ATA1 w wersji dla wysokich temperatur, ATWB1 - termopara przeznaczona do pomiaru temperatury termometru mokrego, ATF1 - termopara o d?ugo?ci 15 cm przeznaczona do p?ynow, ATP1 - termopara przystosowana do przebijania cia? po?sta?ych, ATEXT10 - termopara na 3 m przed?u?aczu, ATC3 - termopara przeznaczona do rur. Pod??czone termopary podaj? Fieldpiece ATH4 odnotowane napi?cie, ktore zostaje prze?o?one na temperatur?, wyra?an? jednak w warto?ciach mVDC (w relacji 0.1º na 0.1mVDC), przez miernik ustawiony na taki zakres. Wy?wietlacz do??czonego miernika poda trzy warto?ci: obu termopar (T1 i T2) oraz Delt? T. Tak jak inne g?owice Fieldpiece, termometr z termoparami mo?na pod??czy? bezpo?rednio do uniwersalnych miernikow. W przypadku innych narz?dzi, jak rejestrator DL3 czy analizator uk?adu HG3, nale?y zastosowa? przewody pomiarowe ADLS2 lub z??czk? uchwytu AHDL1. Termometr ATH4 b?dzie rownie? wspo?pracowa? z ka?dym cyfrowym multimetrem wyposa?onym w standardowe gniazda, o impedancji wej?ciowej 9 lub 10 MOhm. Zalety: podawanie dwoch temperatur oraz ro?nicy mi?dzy tymi warto?ciami w ºF lub ºC, regulowane prosto dwoma prze??cznikami; czujniki termopar (o kszta?cie drobnych kulek na zako?czeniach przewodow) mog? mierzy? temperatur? powietrza lub powierzchni z ktor? maj? kontakt; zdolno?? przeliczania temperatur z zakresu -45 ºC - 980 ºC (do najwy?szych temperatur wymagany dost?pny opcjonalnie rodzaj termopar); termopary izolowane do temperatur rz?du 200 ºC; kszta?t termopar pozwala owija? woko? nich przewod z czujnikiem na czas przechowywania termometru; wtykowe wej?cia termopar umieszczone w niszy g?owicy dla zapewnienia stabilnych warunkow badania; aby u?atwi? pomiar temperatur rur, g?owic? wyposa?ono w dwa paski rzepowe, przytrzymuj?ce ko?cowki termopar przy rurze; technologia zastosowana w g?owicy ?wietnie zdaje egzamin w zakresie kompensacji wp?ywu gwa?townie zmieniaj?cej si? temperatury zewn?trznej, sytuacji cz?stej w codziennej pracy z urz?dzeniem; w warunkach roboczych ca?y uk?ad (termometr z termoparami po??czony z miernikiem) mo?na ?atwo skalibrowa? za pomoc? wody z lodem, z dok?adno?ci? do 1ºC; funkcja auto-off (mo?liwa do wy??czenia) oszcz?dza bateri? urz?dzenia. ATH4, one of the measuring heads that can be used in Fieldpiece gauges or other, allows parallel measuring two temperatures. Since the type of thermocouple used depends on what will be the subject of measurement. Includes user receives two universal thermocouple type K, ATB1. However, the head can also connect other versions: ATA1 - ATB1 with clamp thermocouple (the so-called. Alligator clip) ATAF1 - thermocouple ATA1 version for high temperatures li ATWB1 - thermocouple designed to measure wet bulb temperature ATF1 - thermocouple with a length of 15 cm intended for liquids, ATP1 - thermocouple adapted to pierce the bodies of semi- ATEXT10 - thermocouple extension cable 3 m ATC3 - designed for thermocouple tubes. Connected thermocouples give Fieldpiece ATH4 noted the tension that is translated into heat, but in the values ??expressed mVDC (in relation to 0.1mVDC 0.1º), by the meter set to such a range. The display included with the meter will give three values: the two thermocouples (T1 and T2) and Delta T. Like other heads Fieldpiece, thermocouple thermometer can be connected directly to the universal metrics. For other tools, such as recorder and analyzer system DL3 HG3, use test leads or connector holder ADLS2 AHDL1. ATH4 thermometer will also collaborated with any digital multimeter equipped with a standard socket, input impedance 9 or 10 MW. Highlights: The administration of the two temperatures and the difference between these values ??in F or C, adjustable straight two switches; sensors thermocouples (in the shape of small balls on the ends of the cables) can measure the temperature of the air or surfaces that have contact; The ability of converting temperatures between -45 C - 980 C (the highest temperature required type thermocouples available as an option); insulated thermocouple to a temperature of 200 C; thermocouples shape allows them to wrap around the sensor cable for storage thermometer; Plug-input thermocouple placed in the niche of the head to ensure stable test conditions; to help measure the temperatures of pipes, the head is equipped with two strips of Velcro, holding the ends of thermocouples with pipe; The technology used in the well head passes the test with regard to compensate for the rapidly changing external temperature, frequent situations in everyday work with the device; the operating conditions of the circuit (thermometer with thermocouple connected with a meter) can be easily calibrated using ice water, with an accuracy of 1 C; Auto-off function (possible to switch off) saves the battery of the device. Specyfikacja: Wej?cia: dwie termopary typu K; Wyj?cia: prze??czalne: T1, T2, T1-T2, standardowe wtyki bananowe; Kalibracja: dwa zewn?trzne pokr?t?a regulacyjne; Dok?adno?? konwersji: 1mV DC na 1; Zakres: -46 do 982C; Rozdzielczo??: 0,1 dla miernikow z dok?adno?ci? 0,1mVDC; Bateria: standardowa 9V; ?ywotno?? baterii: 200 godzin ci?g?ej pracy; Automatyczne wy??czanie: po 15 minutach; Kontrolki: zielona wskazuje ?e urz?dzenie jest w??czone, czerwona niski poziom na?adowania baterii; Maksymalne napi?cie wej?ciowe: 60 V DC, 24 V AC. Uwaga: silne pola cz?stotliwo?ci radiowej mog? ujemnie wyp?ywa? na dzia?anie konwertera. Temperatura robocza: -34 do 49C; Temperatura przechowywania: -20 do 60C; Izolacja sondy: teflon, do 260C; Dok?adno?? systemu przy 24C 3C otoczenia, po kalibracji w stosunku do temperatury wody z lodem: 0,5C, -46 do 73C; 1C, 74 do 176C; 2C, 176 do 926C. Dok?adno?? g?owicy: 0,5% + 2C, -46 do 982C. Dok?adno?? termopary: 2C lub 0,75%, w zale?no?ci od tego, ktora z warto?ci jest wi?ksza, -34 do 815C. Inputs: two type K thermocouples; Outputs: switchable: T1, T2, T1-T2 standard banana plugs; Calibration: two external adjustment knobs; Conversion Accuracy: 1 mV dc to 1 ; Range: -46 to 982 C; Resolution: 0,1 for the meter to the nearest 0,1mVDC; Battery: Standard 9V; Battery life: 200 hours of continuous operation; Auto Power Off: After 15 minutes; LEDs: green indicates that the device is switched on, the red low battery; Maximum input voltage: 60 V DC, 24 V AC. Note: strong radiofrequency fields can be highly detrimental to the converter. Operating temperature: -34 to 49 C; Storage temperature: -20 to 60 C; Isolation probe Teflon, to 260 C; The accuracy of the system at 24 C 3 C, ambient, after calibration the temperature of ice-water: 0.5 C, -46 to 73 C; 1 C, 74 to 176 C; 2 C, 176 to 926 C. The accuracy of the head: 0.5% 2 C, -46 to 982 C. Thermocouple accuracy: 2 C or 0.75%, depending on which value is greater, -34 to 815 C. Informacje dodatkowe: W zestawie: termometr ATH4, dwie termopary ATB1, dwa paski rzepowe, mini?rubokr?t do kalibracji, bateria 9V (za?o?ona), instrukcja obs?ugi. Included: thermometer ATH4 Two thermocouples ATB1 two strips of Velcro, mini?rubokr?t for calibration, 9V battery (installed), manual. KLIKNIJ TUTAJ, aby zobaczy? inne produkty firmy Fieldpiece. KLIKNIJ TUTAJ, interesuj? Ci? inne akcesoria do miernika. Cena obowi?zuje wy??cznie przy zakupie poprzez serwis. Zapraszamy rownie? na nasze pozosta?e aukcje WIGMORS ul. Irysowa 5 51-117 Wroc?aw VAT ID / NIP: 915-000-01-99 GWARANCJA I FAKTURY O ile w opisie aukcji wyra?nie nie zaznaczono inaczej, wszystkie sprzedawane przez nas produkty s? nowe i posiadaj? 12-miesi?czn? gwarancj?. Wystawiamy faktury VAT. WARUNKI P?ATNO?CI - przelew z gory - pobranie - gotowka lub karta p?atnicza (przy odbiorze osobistym) RACHUNEK BANKOWY PEKAO S.A. 03 1240 6670 1111 0000 5641 0448 WYSY?KA I KOSZTY Standardowo towar wysy?amy poczt? kuriersk?. Na ?yczenie towar mo?emy wys?a? rownie? za po?rednictwem poczty. Nie dotyczy to jednak wyrobow o znacznej wadze, gabarytach lub o du?ej warto?ci. Szczego?owe informacje o kosztach wysy?ki danego towaru znajduj? si? w opisie aukcji. Koszt wysy?ki pocztowej podajemy na zapytanie. ODBIOR OSOBISTY - Wroc?aw Irysowa - bez op?at W nast?puj?cych miastach - dop?ata 20 PLN: - D?bica - Gorzow Wlkp. - Katowice - Koszalin - Krakow (2 placowki) - Nowy S?cz - Pozna? - Szczecin - Tarnow Prosimy mie? na uwadze, ?e w przypadku odbioru produktu w danym mie?cie termin odbioru mo?e ulec wyd?u?eniu, ze wzgl?du na konieczno?? wys?ania (zwykle nie d?u?ej ni? do 1 tyg.).